11.6.33Error34:Powerfailfunkctionerror
11.6.33.1Error34-0(emergencycode3220h)
Cause: Power fail detected and reaction active
Suggested steps:
Check net connection of servo
Anunder-voltageoccurred
onthedrivewhilethisaxis
wasswitchedon.
l Powersupplywaspossiblyswitchedoff.
l Pleasecheckiftheactualgridvoltagematches
thesupplysetting(parameterPST_
VoltageSupply)
l Verifythatthegridisstableunderload
condition.
11.6.33.2Error34-1(emergencycode3220h)
Cause: Returning DC-link voltage detected
Suggested steps:
Restart Device
Anunder-voltageoccurred
onthedrivewhilethisaxis
wasswitchedon.
l Powersupplywaspossiblyswitchedoff.
l Pleasecheckiftheactualgridvoltagematches
thesupplysetting(parameterPST_
VoltageSupply)
l Verifythatthegridisstableunderload
condition.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
420
11 Alarms & warnings
11.6.33.3Error34-2(emergencycode3220h)
Cause: Power fail initialization failed
Suggested steps:
Check power fail parameter settings
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.