EasyManua.ls Logo

Keba ServoOne - Error 30: Control Initialization Error

Keba ServoOne
493 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.6.28.3Error28-3(emergencycode7307h)
Cause: Channel 3 cyclic, Np (distance coded): error, calculated 'delta' is out of range
Suggested steps:
Please check the wiring of the encoder
Encoderchannel,cyclic
evaluation
l Errorduringthecyclicevaluationofan
encoderchannel3.
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.
l Themostcommoncauseoferroristhewiring
totheencoder.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
413
11 Alarms & warnings
11.6.29Error30:Controlinitializationerror
11.6.29.1Error30-1(emergencycode5300h)
Cause: Initializationerroranalogueinput
Suggested steps:
Check calibration of analog inputs
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.

Table of Contents