11.6.42Error45:Lockviolationerror
11.6.42.1Error45-0(emergencycode8612h)
Cause: Unknown lock violate error
Suggested steps:
Switch off/on device. Please contact your service provider if this error occurs again
Thereferencevalueviolates
alockorlimitswitch.
l Pleasecheckreferencevalues.Ifthisaxisis
workingincyclicsynchronousmode,makea
scoperecord.
l Checkfactorgroupsettings.
l Checkmodeofoperation.
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
436
11 Alarms & warnings
11.6.42.2Error45-1(emergencycode8612h)
Cause:
Movementrequestedwhichwaslimitedbyreversinglock,limitswitchorreferencev
aluelimitation.
Suggested steps:
Quit error and change reference value
Thereferencevalueviolates
alockorlimitswitch.
l Pleasecheckreferencevalues.Ifthisaxisis
workingincyclicsynchronousmode,makea
scoperecord.
l Checkfactorgroupsettings.
l Checkmodeofoperation.
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.