EasyManua.ls Logo

Keba ServoOne - Error 41: Fast Discharge Monitoring Error (DC-Link)

Keba ServoOne
493 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.6.38.9Error40-8(emergencycode7300h)
Cause: Tech-Option initialisation error
Suggested steps:
Error in TwinSync mapping configuration
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
434
11 Alarms & warnings
11.6.39Error41:Fastdischargemonitoringerror(dc-
link)
11.6.39.1Error41-0(emergencycode7300h)
Cause: Maximumperiodforfastdischargeexceeded(35s)
Suggested steps:
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.

Table of Contents

Related product manuals