11.6.45.3Error49-2(emergencycode6100h)
Cause: Alarm on safety controller SR2 of master or local device detected
Suggested steps:
Read additional information, check safety system or wiring and acknowledge
alarm/error
Extendeddiagnosisofsafety
errors/alarms.
l Furtherinformationontheerror/alarmcode
canbefoundinthe"ServoOnefunctional
SafetyErrorDescription".
Analarmoccuredatthe
safetycontroller.
l Pleasecheckthesafetyprogramandthe
wiringofthesafetysystem.
l Pleaseacknowledgethealarmatthesafety
master.Thesafetymasteracknowledgesall
slavealarmsandresetsthenetworkstatusto
"RUN".
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
443
11 Alarms & warnings
11.6.45.4Error49-3(emergencycode6100h)
Cause: Alarm on safety controller SR1 of Slave 1 detected
Suggested steps:
Read additional information, check safety system or wiring and acknowledge
alarm/error
Extendeddiagnosisofsafety
errors/alarms.
l Furtherinformationontheerror/alarmcode
canbefoundinthe"ServoOnefunctional
SafetyErrorDescription".
Analarmoccuredatthe
safetycontroller.
l Pleasecheckthesafetyprogramandthe
wiringofthesafetysystem.
l Pleaseacknowledgethealarmatthesafety
master.Thesafetymasteracknowledgesall
slavealarmsandresetsthenetworkstatusto
"RUN".