11.6.20.3Error19-3(emergencycode5400h)
Cause: PST:InvalidEEPROMdata
Suggested steps:
Call your service provider.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.
11.6.20.4Error19-4(emergencycode5400h)
Cause: PST:CRCerror
Suggested steps:
Call your service provider.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
381
11 Alarms & warnings
11.6.20.5Error19-5(emergencycode5400h)
Cause: PST:Errorreadingpowerstagedata
Suggested steps:
Call your service provider.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.
11.6.20.6Error19-6(emergencycode5400h)
Cause: PST:Errorwritingpowerstagedata
Suggested steps:
Call your service provider.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.