EasyManuals Logo

Keba ServoOne User Manual

Keba ServoOne
493 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #379 background imageLoading...
Page #379 background image
11.6.19.5Error18-5(emergencycodeFF00h)
Cause: Homing:Homingmethodavailablebutnotdefined
Suggested steps:
Homing is not available with this motion profile. Please select another homing
method.
11.6.19.6Error18-6(emergencycodeFF00h)
Cause:
Homing:Drivenotreadyforhoming:Erroristriggeredwhenthemotorisnotstopped
,orthestandstillbitisnotset(Standstillwindow).
Suggested steps:
Please stop the motor. Check the positon window parameter 746 [0] (subject area
limits).
11.6.19.7Error18-7(emergencycodeFF00h)
Cause: Homing:Drivenotreadyforjogmode
Suggested steps:
Please stop the motor. Check the position window parameter 746 [0] (subject area
limits).
11.6.19.8Error18-8(emergencycodeFF00h)
Cause: Homing:Controlmodedoesnotmatchhomingmethod
Suggested steps:
Homing is only possible in position control mode.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
379
11 Alarms & warnings
11.6.19.9Error18-9(emergencycodeFF00h)
Cause: Homing:Encoderinitializationerror
Suggested steps:
The homing during device start-up was not performed due to an internal error.
Please restart the application (24V reset).
Anerroroccuredatthe
homingmethode.
l Pleaseacknowledgetheerror.
l Pleasestartthehomingmethodagain.
11.6.19.10Error18-10(emergencycodeFF00h)
Cause: Homing:Homingtravelexceeded
Suggested steps:
l Thezeropulsehasnotbeenreachedwithinthepermissibledistance.Please
checkthezeropulseoftheencoderandtheparameter169[0]forthe
maximumdistance.
l Pleasecheckwhethertheencoderisworkingcorrectly.
11.6.19.11Error18-11(emergencycodeFF00h)
Cause: Max.permissibletrackingerroron"Startcontrol"exceeded
Suggested steps:
Reset error and start again
Anerroroccuredatthe
homingmethode.
l Pleaseacknowledgetheerror.
l Pleasestartthehomingmethodagain.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keba ServoOne and is the answer not in the manual?

Keba ServoOne Specifications

General IconGeneral
BrandKeba
ModelServoOne
CategoryController
LanguageEnglish

Related product manuals