11.6.19.5Error18-5(emergencycodeFF00h)
Cause: Homing:Homingmethodavailablebutnotdefined
Suggested steps:
Homing is not available with this motion profile. Please select another homing
method.
11.6.19.6Error18-6(emergencycodeFF00h)
Cause:
Homing:Drivenotreadyforhoming:Erroristriggeredwhenthemotorisnotstopped
,orthestandstillbitisnotset(Standstillwindow).
Suggested steps:
Please stop the motor. Check the positon window parameter 746 [0] (subject area
limits).
11.6.19.7Error18-7(emergencycodeFF00h)
Cause: Homing:Drivenotreadyforjogmode
Suggested steps:
Please stop the motor. Check the position window parameter 746 [0] (subject area
limits).
11.6.19.8Error18-8(emergencycodeFF00h)
Cause: Homing:Controlmodedoesnotmatchhomingmethod
Suggested steps:
Homing is only possible in position control mode.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
379
11 Alarms & warnings
11.6.19.9Error18-9(emergencycodeFF00h)
Cause: Homing:Encoderinitializationerror
Suggested steps:
The homing during device start-up was not performed due to an internal error.
Please restart the application (24V reset).
Anerroroccuredatthe
homingmethode.
l Pleaseacknowledgetheerror.
l Pleasestartthehomingmethodagain.
11.6.19.10Error18-10(emergencycodeFF00h)
Cause: Homing:Homingtravelexceeded
Suggested steps:
l Thezeropulsehasnotbeenreachedwithinthepermissibledistance.Please
checkthezeropulseoftheencoderandtheparameter169[0]forthe
maximumdistance.
l Pleasecheckwhethertheencoderisworkingcorrectly.
11.6.19.11Error18-11(emergencycodeFF00h)
Cause: Max.permissibletrackingerroron"Startcontrol"exceeded
Suggested steps:
Reset error and start again
Anerroroccuredatthe
homingmethode.
l Pleaseacknowledgetheerror.
l Pleasestartthehomingmethodagain.