Configuring Alarm Entries in the Central Alarm Table: Configuring an Alarm Entry for a Serial Connection
Failure
15-13
4. (optional) Verify that the alarm entry has been configured properly:
show alarm-entries name SerConnFail
The command response appears similar to the following:
5. Save the configuration.
(Dub)>show alarm-entries name SerConnFail
Name - SerConnFail
State - normal
Current Message -
Description - Serial connection failure
Nagging Interval - 0
Nagging Level - major
Trap - enabled
Raw - disabled
TL1 - disabled
TL1 AID -
TL1 Class - env
TL1 Affect - nsa
TL1 Type -
TL1NE - 1
Category -
NE Name -
Alarm Actions:
Severity Originator Trigger Message
------------------------------------------------------------------
major serial 3 conn-faile The serial connectio
(Dub)>