Remote RMX-3200 Version 5.2x Configuration Guide
Configuring Alarm Entries in the Central Alarm Table: Configuring an Alarm Entry for a TCP Connection
that Goes Down
15-16
Configuring an Alarm Entry for a TCP Connection that
Goes Down
To configure an alarm entry for a TCP connection that goes down:
1. At the main prompt, configure description
TCP connection down:
config alarm-entry TCPConnDown description TCP connection down
2. Enable SNMP trap alarm protocol support:
config alarm-entry TCPConnDown trap enable
3. Configure an event for alarm entry TCPConnDown with the following settings:
Event originator tcp 192.168.0.12:5001
Event trigger conn-down
Event severity level major
Alarm event message TCP connection down.
config alarm-entry TCPConnDown event tcp 192.168.0.12:5001 conn-
down major TCP connection down
In this scenario, you will:
Configure an alarm entry description
Configure SNMP alarm protocol support
Configure an alarm action that signals that a TCP connection has gone down.