Remote RMX-3200 Version 5.2x Configuration Guide
Drop and Continue Functionality: Functional Specifications
27-4
Configuration
Remote RMX-3200 models with DAC capabilities do not have any configuration
commands beyond those that are available for non-DAC models. However, there are
notable differences between the dual-WAN and DAC Remote RMX-3200 models. The
following commands exhibit these differences:
config controller serial clock
This command does not exist for DAC Remote RMX-3200 models. Clocking for DAC
is set internally and cannot be changed.
config controller serial buildout (for controller serial wan/2)
This command does not exist for DAC Remote RMX-3200 models. The buildout level
is set to
0to133ft for DAC and cannot be changed.
config controller serial framing (for controller serial wan/2)
This command does not exist for DAC Remote RMX-3200 models. The framing for
both links must match, so the framing for serial wan/2 follows the framing for serial
wan/1 automatically.
config controller serial linecode (for controller serial wan/2)
This command does not exist for DAC Remote RMX-3200 models. The linecode for
both links must match, so serial wan/2 linecode follows serial wan/1 linecode
automatically.
config controller serial channel-group (for controller serial wan/1)
Command config controller serial channel-group group timeslots defines
the set of T1/E1 channels that comprise the channel-group. These channels are
dropped from the data stream (and the data from these channels goes to Remote
RMX-3200's CPU) and the remaining channels continue on to serial wan/2.
Note: Remote RMX-3200 fills the dropped channels with all 1s when it transmits
data on serial wan/2.
config controller serial channel-group (for controller serial wan/2)
This command does not exist for DAC Remote RMX-3200 models. Data from
channels on serial wan/2 in a DAC model cannot be routed to Remote RMX-3200's
CPU. To do this, you must access a router or bridge with serial wan/1.