Remote RMX-3200 Version 5.2x Configuration Guide
Configuring the Peripheral Management Subsystem: Configuring Alarms for an Expansion Peripheral
25-18
3. (optional) Verify that the alarm entries have been configured properly:
show alarm-entries name serConnDown
The display will look similar to the following for alarm entry serConnDown:
show alarm-entries name serConnUp
The display will look similar to the following for alarm entry serConnUp:
4. Save the configuration.
(Dub)>show alarm-entries name serConnDown
Name - serConnDown
State - normal
Current Message -
Description -
Nagging Interval - 0
Nagging Level - major
Trap - enabled
Raw - disabled
TL1 - disabled
TL1 AID -
TL1 Class - env
TL1 Affect - nsa
TL1 Type -
TL1NE - 1
Category -
NE Name -
Alarm Actions:
Severity Originator Trigger Message
------------------------------------------------------------------
major serial 3/5 down Serial controller 3/
(Dub)>
(Dub)>show alarm-entries name serConnUp
Name - serConnUp
State - normal
Current Message -
Description -
Nagging Interval - 0
Nagging Level - major
Trap - enabled
Raw - disabled
TL1 - disabled
TL1 AID -
TL1 Class - env
TL1 Affect - nsa
TL1 Type -
TL1NE - 1
Category -
NE Name -
Alarm Actions:
Severity Originator Trigger Message
------------------------------------------------------------------
normal serial 3/5 up Serial controller 3/
(Dub)>