Remote RMX-3200 Version 5.2x Configuration Guide
Configuring Network Setup Parameters: Configuring System Clock Settings
5-9
2. Set the following custom daylight savings time parameters:
3. (optional) Verify that the clock parameters have been configured properly:
show clock
The command response similar to the following displays:
4. Save the configuration.
(Dub)>config
(Dub) config>clock
(Dub) config clock>daylight-savings
(Dub) config clock daylight-savings
->indicator EDT
(Dub) config clock daylight-savings
->start-month march
(Dub) config clock daylight-savings
->start-day 23
(Dub) config clock daylight-savings
->start-time 01:00:00
(Dub) config clock daylight-savings
->end-month november
(Dub) config clock daylight-savings
->end-time 02:00:00
(Dub) config clock daylight-savings
->save-amount 01:45:00
(Dub) config clock daylight-savings
->
(Dub)>show
(Dub) show>clock
Fri Apr 9 14:18:24 EST 2010
Uptime 9 days, 17:48
The timezone is named EST and has an offset of -05:00 GMT.
Daylight savings time is named EDT and using custom rules:
Starts on 23 of March at 01:00:00, saving 01:45:00.
Ends on 23 of November at 02:00:00.
Log timestamps are using GMT.
(Dub) show>