EasyManua.ls Logo

LG-Ericsson ipldk-60 - Page 353

LG-Ericsson ipldk-60
512 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ipLDK-60 Issue 2.0
Admin Programming Manual July, 2010
78
PGM
152
Flex
Btn
Description Default Values
Out-pulse Rate 6 not used
Seize Timer 7 This parameter defines the duration of the seizure signal provided by the T1 CO line
for DID and TIE lines.
3 (60 milli-
seconds)
000 ~ 127 in 20-milli-
second increments
Release Timer 8 This parameter defines the duration of the release signal provided by the T1 CO line
for DID and TIE lines.
7 (140 milli-
seconds)
000 ~ 127 in 20-milli-
second increments
IASG Mode 9 not used 1 (DTMF) 0 = Pulse
1 = DTMF
Ring Detect Time 10 This parameter defines the minimum incoming Ring-on signal to be considered a
valid ring signal for Loop/Ground Start T1 CO lines. Shorter ring-on periods are
ignored.
2 (200 milli-
seconds
2 ~ 9 in 100-milli-
second increments
Ring Stop Time 11 This parameter defines the maximum duration of the Ring-off period to be
considered a valid ring signal for Loop/Ground Start T1 CO lines. Longer Ring-off
signals are considered an abandoned call.
60 (6 seconds) 10 ~ 60 in 100-milli-
second increments
Collect Digit
Timer
12 not used
Store Timer 13 not used

Table of Contents

Other manuals for LG-Ericsson ipldk-60