3.5.21.3 System Timers III (PGM 182)
PGM 182 is one of three PGMs used to define timers that affect system wide operations. See also PGM 180 and 181.
Procedure:
1. Press the [TRANS PGM] button.
2. Dial 182.
3. Select the desired Flexible button.
4. Enter the appropriate value.
5. Press the [Hold/Save] button.
PGM
182
Flex
Btn
Description Default Values
SLT Hook Switch
Bounce Timer
1 This parameter defines the duration of a hook-switch transition considered a
spurious signal and ignored. If the signal is stable for a period longer than the
bounce time, it is considered a valid hook switch transition.
01 (100 milli-
seconds)
01 ~ 25 in 100 milli-
second increments
SLT Maximum
Hook Flash Timer
2 This parameter sets the maximum duration of a Flash (new dial tone request) from
an SLT. An open hook switch signal longer than the maximum is considered a
disconnect signal from the SLT.
075 (750 milli-
seconds)
001 ~ 250 in 10 milli-
second increments
SLT Minimum
Hook Flash Timer
3 This parameter defines the minimum duration of a Flash (new dial tone request) for
the ipLDK to register the Flash signal otherwise the signal is consider a spurious
signal.
020 (200 milli-
seconds)
000 ~ 250 in 10 milli-
second increments
SLT Ring Phase
Timer
4 This parameter defines the overall duration of ring signal sent to an SLT port. The
Ring-on period is fixed at 1 second. The remaining time is the Ring-off period. The
default is 1 second Ring-on and 4 seconds Ring-off for a total duration of 5 seconds.
5 seconds 2 ~ 5 in 1 second
increments
Station Auto
Release Timer
5 This parameter sets the length of time a station receives intercom Ring Back tone
before the call attempt is abandoned and error tone provided to the station. Also, the
060 seconds 020 ~ 300 in 1
second increments