ipLDK-60 Issue 2.0
Admin Programming Manual July, 2010
91
3.5.7 CO-To-CO COS (PGM 166)
PGM 166 assigns the Day and Night/Weekend service mode COS for a CO-to-CO connection (Unsupervised Conference).
Procedure:
1. Press the [TRANS PGM] button.
2. Dial 166.
3. Select the desired Flexible button.
4. Enter the appropriate value.
5. Press the [Hold/Save] button.
PGM
166
Flex
Btn
Description Default Values
CO to CO Day
COS
1 This parameter defines the CO-to-CO Day mode COS. Refer to the table below for
COS values.
07 01 ~ 11
CO to CO Night
COS
2 This parameter defines the CO-to-CO Night and Weekend COS. Refer to the table
below for COS values.
07 01 ~ 11
CO to CO COS Table
Station COS Restrictions
1 No restrictions are placed on dialing.
2 The assignments in the Exception Table A are monitored for Allow and Deny numbers.
3 The assignments in the Exception Table B are monitored for Allow and Deny numbers.
4 The assignments in both Exception Tables A & B are monitored for Allow and Deny numbers.
5
The leading digit dialed cannot be a long distance code. The dialed digits can be longer than
7 digits. There is no restriction for the number in Canned Toll Table.