ipLDK-60 Issue 2.0
Admin Programming Manual July, 2010
181
3.11.2 Networking Supplementary Attributes (PGM 321)
PGM 321 configures signaling for supplementary features and characteristics of the BLF Manager.
Procedure:
1. Press the [TRANS PGM] button.
2. Dial 321.
3. Select the desired Flexible button.
4. Enter the appropriate value.
5. Press the [Hold/Save] button.
PGM
321
Flex
Btn
Description Default Values
Networking
Transfer Mode
1 This parameter determines the signaling employed for call transfer over the
network. The Join or Reroute method is available.
1 (Reroute) 0 = Join
1 = Reroute
TCP Port 2 This parameter defines the TCP port used for communications with the BLF
Manager.
9000 0000 ~ 9999
UDP Port 3 This parameter defines the UDP port used for communications with the BLF
Manager.
9001 0000 ~ 9999
BLF Manager IP
Address
4 This parameter defines the IP address of the server hosting the BLF Manager. 0.0.0.0 IPv4 address
Duration of BLF
status
5 This parameter sets the maximum duration between BLF status messages. 02 seconds 01 ~20 in 1 second
increments
Multicast IP
Address
6 This parameter defines the IP multi-cast address used by the BLF Manager. 0.0.0.0 IPv4 address
Net Trans Fault
Recall Timer
7 This parameter sets the time interval the system waits for a response from a
networked system when transferring a call. After expiration of the timer, the
010 seconds 001 ~ 300 in 1
second increments