3.5.4 Alarm Attributes (PGM 163)
PGM 163 configures the Alarm contact in the main cabinet.
Procedure:
1. Press the [TRANS PGM] button.
2. Dial 163.
3. Select the desired Flexible button.
4. Enter the appropriate value.
5. Press the [Hold/Save] button.
PGM
163
Flex
Btn
Description Default Values
Alarm Enable 1 If this parameter is ‘On’, the system will monitor the external Alarm contact. 0 (Off) 0 = Off
1 = On
Alarm Contact
Type
2 This parameter defines the contact state (open or close) that activates the Alarm
signal.
1 (Close) 0 = Open
1 = Close
Alarm Mode 3 This parameter determines the operating mode of the contact, Alarm or Doorbell. 1 = Alarm 0 = Doorbell
1 = Alarm
Alarm Signal
Mode
4 This parameter determines if the Alarm signal is a single or repeating tone. Users to
receive the Alarm signal are defined in PGM 113, Flexible button 10.
1 (Repeat) 0 = Once
1 = Repeat