ipLDK-60 Issue 2.0
Admin Programming Manual July, 2010
126
3.6 DCOB ATTRIBUTE (PGM 186–PGM 187)
3.6.1 DCOB Attributes I (PGM 186)
PGM 186 is one of several programs that define attributes of digital (E1R2) lines, also see PGM 187.
Procedure:
1. Press the [TRANS PGM] button.
2. Dial 186.
3. Enter the appropriate CO Line range
4. Select the desired Flexible button.
5. Enter the appropriate value.
6. Press the [Hold/Save] button.
PGM
186
Flex
Btn
Description Default Values
DCOB TYPE 1 See PGM 187, Flexible button 4
Metering Type 2 When enabled (On), this parameter enables the use of Call Metering signals. Also,
see PGM 142, Flexible buttons 3.
0 (Off) 0 = Off
1 = On
R2 OUT Manage
Timer
3 This parameter sets the time the system will wait for a “backward signal” from an
E1R2 CO line after sending a “forward signal” on an outgoing call.
14 seconds 01 ~ 50 in 1 second
increments
R2 IN Manage
Timer
4 This parameter sets the time the system will wait for a “forward signal” from an E1R2
CO line after sending a “backward signal” on an incoming call.
14 seconds 01 ~ 50 in 1 second
increments
R2 Disappear
Timer
5 This parameter defines the duration the system will allow to complete R2 signaling. 14 seconds 01 ~ 50 in 1 second
increments
R2 Pulse Timer 6 This parameter sets the duration of pulse dial signals sent over an E1R2 Co line. 07 (140 milli- 01 ~ 30 in 20-milli-