ipLDK-60 Issue 2.0
Admin Programming Manual July, 2010
119
3.5.21.2 System Timers II (PGM 181)
PGM 181 is one of three PGMs used to define timers that affect system wide operations. See also PGM 180 and 182.
Procedure:
1. Press the [TRANS PGM] button.
2. Dial 181.
3. Select the desired Flexible button.
4. Enter the appropriate value.
5. Press the [Hold/Save] button.
PGM
181
Flex
Btn
Description Default Values
Call Forward No
Answer Timer
1 This parameter sets the No-answer Forward time, if No-answer Call Forward is
active at the station, when the timer expires the call is rerouted to the designated
destination.
015 seconds 000 ~ 255 in 1
second increments
DID/DISA No
Answer Timer
2 This parameter sets the time a DID/DISA call will ring the station before it is rerouted
to the DID/DISA No-answer destination (PGM 167, Flexible button 3).
25 seconds 00 ~ 99 in 1 second
increments
VMIB User
Record Timer
3 This parameter determines the maximum duration of the user recorded greeting for
the VMIB Voice Mail. Longer greetings cannot be stored.
020 seconds 010 ~ 255 in 1
second increments
VMIB Valid User
Message Timer
4 This parameter establishes the minimum duration the ipLDK will recognize as a
legitimate Voice Mail, shorter messages are discarded. If set to ‘0’, a message
cannot be recorded in the VMIB.
4 seconds 0 ~ 9 in 1 second
increments
Door Open Time 5 This parameter sets the duration the Door Open contact will remain activated when a
station dials the Door Open code.
20 (2 seconds) 05 ~ 99 in 100 milli-
second increments
ICM Box Timer 6 This parameter sets the duration a station receives Door Phone ring when the Door
Phone ‘Call’ button is pressed.
30 seconds 00 ~ 60 in 1 second
increments

Table of Contents