ipLDK-60 Issue 2.0
Admin Programming Manual July, 2010
121
PGM
181
Flex
Btn
Description Default Values
line to setup before receiving digits.
VMIB Message
Rewind Timer
17 This parameter determines the length of time the system will rewind a voice
message using the Message Rewind function in the VMIB.
03 seconds 01 ~ 99 in 1 second
increments
LCO Connect
Timer
18 If this timer expires after starting outgoing dial, the system regards the call as
connected. At expiration, any further dialed digits are ignored for the purposes of
redial. In this way, digits, which may be dialed into an automated service such as
banking, are not stored in the Last Number Redial buffer.
00 (disabled) 00 ~ 30 in 1 second
increments
LCO CPT Detect
Timer
19 This parameter sets the duration the system periodically removes the CPT detector
from a CO line that is transferred or forwarded to another CO line. After the
assigned time, a CPT detector is connected to the CO line to detect busy or error
tone for 7 seconds. The detector is then removed from the line and reconnected at
expiration of the timer. This process continues until the connection is terminated.
This timer applies to Busy/Error CPT in PGM 142, Flexible button 18.
05 seconds 00 ~ 20 in 1 second
increments
Forward To VMIB
Timer
20 This parameter sets the duration a station receives ring before the call forwards to
the VMIB when Auto Forward To VMIB (PGM113, Flexible button 14) is enabled.
20 seconds 01 ~ 60 in 1 second
increments