56
Procedure for Settin
g
Ins
p
ection Conditions
Cha
p
ter 5
5.1 Setting Inspection Conditions
Set the inspection conditions in the following order. The details of each step are described in the next page or
later.
1 Select a camera mode.
Select a type or mode of the connected camera, or if
necessary, select shutter speed.
Sections
5.2 and 5.3
Camera mode and shutter speed is common to all product
types.
2 Select a product type No.
Select the number of a product type in which a combination of
inspection conditions is stored.
Section 5.4
Available product type numbers: 1 – 64
2-a
If you want to execute some of the checkers in the
product type, set the PV310 to SETUP mode.
Section 7.2
3
Capture the image of the
inspection object.
Put the inspection object under the camera lens and capture
the image into the memory.
Section 5.5
4 Set a checker. Set a inspection area and conditions Section 6
4-a
If you let the PV310 compute using each detected
value, use the Numeric Calculation function.
If you output each detected value to the external
device, save the data as Numeric Calculation data
and output it.
Section 7.2
5
Configure the settings for
outputting judgment result to
the external device.
Configure the settings for outputting inspection judgment
result OK or NG to the external device.
Section 7.1.2
5-a
If you output the
settings data
configured at the
step 4-a, set the
way of outputting
the settings data or
output format.
Refer to page 219 for setting output
destination.
For parallel communication: Section 10
For serial communication: Section 11
For Ethernet communication: Section 12
For Compact flash memory card: Section
13.5
6 Display the inspection result.
Display Judgment result (OK or NG) in the total Judgment
result display area.
Section 0
7 Save the setting data Store the setting data in PV310. Section 5.7
8 Execute inspection Execute inspection by changing to RUN mode. Section 5.8

Table of Contents