131
3. Click the icon of the logical drive you want to Initialize.
You can also start Redundancy check from the Subsystem icon
Background Activities tab
4. From the dropdown menu on the Background Activities tab, choose
Redundancy Check.
5. To choose Auto Fix, check the box.
This feature attempts to repair the problem when it finds an error.
6. To choose Pause On Error, check the box.
This feature stops the process when it finds an error.
If Auto Fix is also checked, the process stops only when it finds a non-
repairable error.
7. Click the Submit button.
To view the progress of the Redundancy Check, click the Background Activity
tab.
To set Redundancy Check priority, see “Making Background Activity Settings” on
page 56.
Viewing the Logical Drive Check Table
The Logical Drive Check Table displays errors related to a logical drive. Use this
information to evaluate the integrity of the logical drive and to determine whether
corrective action is needed. To View the tables:
1. Click the Subsystem icon in Tree View.
2. Click the Disk Arrays icon.
3. Click the Disk Array icon.
4. Click the Logical Drives icon
5. Click the Logical Drive icon.
6. Click the Check Table tab in Management View.
7. Click the option for the table you want to see.
The default is All tables.
If there are entries, they are listed as follows:
Entry Number – A number assigned to each block of entry.
Table Type – Read Check, Write Check or Inconsistent Block (see
below).
Start Logical Block Address – LBA of the first block for this entry.
Count – Number of continuous blocks starting from this LBA.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology VessRAID 1720i and is the answer not in the manual?

Promise Technology VessRAID 1720i Specifications

General IconGeneral
BrandPromise Technology
ModelVessRAID 1720i
CategoryEnclosure
LanguageEnglish

Related product manuals