266
RAID 1
A RAID 1 Source logical drive can migrate to the following Target logical drives:
RAID 1E
A RAID 1E Source logical drive can migrate to the following Target logical drives:
Target Requirements
RAID 0 None.
RAID 1E 3 or more physical drives.
Add 1 or more physical drives.
RAID 5 3 physical drives minimum, 16 maximum.
RAID 1 must have less than 16 physical drives.
Add 1 or more physical drives.
RAID 10 4 physical drives minimum.
Even number of physical drives.
Add 2 or more physical drives.
RAID 50 6 physical drives minimum, 32 per axle maximum.
Add 4 or more physical drives.
Target Requirements
RAID 0 None.
RAID 1E Add physical drives.
RAID 5 3 physical drives minimum, 16 maximum.
RAID 1E must have less than 16 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 4 physical drives minimum.
Even number of physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 50 6 physical drives minimum, 32 per axle maximum.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology VessRAID 1720i and is the answer not in the manual?

Promise Technology VessRAID 1720i Specifications

General IconGeneral
BrandPromise Technology
ModelVessRAID 1720i
CategoryEnclosure
LanguageEnglish

Related product manuals