VessRAID 1000i Series Product Manual
234
When the controller shuts down, your WebPAM PROe connection will be
lost.
9. Wait for two to three minutes.
10. In your browser, log into WebPAM PROe once again.
If you cannot log in, wait for 30 seconds, and try again. Repeat until login is
successful.
Updating the Firmware in the CLU
A firmware update consists of the following actions:
• Downloading the Firmware Image File (page 234)
• Updating the Firmware (page 234)
• Restarting Subsystem over a Telnet Connection (page 235)
• Restarting Subsystem over a Serial Connection (page 235)
Downloading the Firmware Image File
Go to the Promise website at http://www.promise.com/support/support_eng.asp
and download the latest firmware image file to your TFTP server.
Updating the Firmware
To update the firmware file in the CLU:
1. From the Main Menu, highlight Additional Info and Management, and press
Enter.
2. Highlight Flash through TFTP and press Enter.
3. Highlight TFTP Server and type the IP address of your TFTP server in the
field provided.
4. Highlight Port Number and press the backspace key to erase the current
value, then type the new value. 69 is the default.
A list of the current users appears.
5. Highlight File Name and type the file name of the firmware image file in the
field provided.
6. Highlight Start and press Enter.
A message appears to tell you to reboot the VessRAID.
7. Restart the VessRAID.
See “Restarting Subsystem over a Telnet Connection” on page 235 or
“Restarting Subsystem over a Serial Connection” on page 235.