Chapter 5: Management with the CLU
205
Shutting down the VessRAID – Serial Connection
This function enables you to shutdown the VessRAID subsystem on a serial
connection. Additional action is required, as described below.
To shutdown the VessRAID:
1. From the Main Menu, highlight Additional Info and Management and press
Enter.
2. Highlight Shutdown or Restart and press Enter.
3. Do one of the following actions:
• Highlight Option and press the spacebar to display Shutdown.
• Highlight Option and press the spacebar to display Poweroff.
4. Highlight Submit and press Enter.
A warning message appears.
5. Press Y to continue.
6. When you see the following message:
Shutdown complete. It is now safe to power off the subsystem.
Do one of the following actions:
• If you chose the Shutdown Option, manually turn off the power supply
switch (both switches with redundant power supplies) on the back of the
subsystem.
• If you chose the Poweroff Option, the subsystem powers down
automatically. On subsystems with redundant power supplies, unplug
the power cords and plug them back in, to activate the power switches.
Caution
After you power off the subsystem, wait at least 10 seconds before
you power on the subsystem again.