EasyManuals Logo

Promise Technology VessRAID 1720i User Manual

Promise Technology VessRAID 1720i
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #190 background imageLoading...
Page #190 background image
VessRAID 1000i Series Product Manual
174
Running Redundancy Check
Redundancy Check is a maintenance procedure for logical drives in fault-tolerant
disk arrays that ensures all the data matches exactly. To run Redundancy Check:
1. From the Main Menu, highlight Logical Drive Management and press Enter.
2. Highlight the logical drive you want and press Enter.
3. Highlight Background Activity and press Enter.
4. Highlight Start Redundancy Check and press Enter.
The redundancy check parameters appear.
• Auto Fix – Corrects inconsistencies automatically
• Pause On Error – Pauses the Redundancy Check when an error is
found
To change a parameter, highlight it and press the backspace toggle between
Yes and No.
5. Highlight Start and press Enter.
If necessary, you can pause and resume or stop and restart the Redundancy
Check. You can use the logical drive while Redundancy Check is running.
Locating a Logical Drive
This feature helps you identify the physical drives assigned to the logical drive
you are working with in the CLU. To locate a logical drive:
1. From the Main Menu, highlight Logical Drive Management and press Enter.
2. Highlight the disk array you want and press Enter.
3. Highlight Locate Logical Drive and press Enter.
The disk status LEDs for the physical drives in this logical drive blink for one
minute.
Figure 9. Disk Status LED
Disk Status

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology VessRAID 1720i and is the answer not in the manual?

Promise Technology VessRAID 1720i Specifications

General IconGeneral
BrandPromise Technology
ModelVessRAID 1720i
CategoryEnclosure
LanguageEnglish

Related product manuals