VessRAID 1000i Series Product Manual
198
Making Telnet Settings
By default, Telnet service is set to Automatic and its normal status is Started. To
make Telnet service settings:
1. From the Main Menu, highlight Additional Info and Management and press
Enter.
2. Highlight Software Management and press Enter.
3. Highlight Telnet and press Enter.
4. Highlight Startup Type and press the spacebar to toggle between Automatic
and Manual.
5. Highlight the following and press the backspace key to erase the current
value, then type the new value:
• Port number (2300 is the default)
• Session Time Out (24 minutes is the default. 1440 minutes = 24 hours)
• Maximum number of connections (4 is the default)
6. Press Ctrl-A to save your settings.
To start, stop or restart the Telnet service, highlight Start, Stop, or Restart and
press Enter.
Making SNMP Settings
By default, SNMP (Simple Network Management Protocol) service is set to
Automatic and its normal status is Started.
To make SNMP service settings:
1. From the Main Menu, highlight Additional Info and Management and press
Enter.
2. Highlight Software Management and press Enter.
3. Highlight SNMP and press Enter.
4. Highlight Startup Type and press the spacebar to toggle between Automatic
and Manual.
5. Highlight the following and press the backspace key to erase the current
value, then type the new value:
• Port Number – 161 is the default
• System Name – (optional) Type a system name in this field
• System Location – Type a country name in this field
• System Contact – Type the email address of your system administrator
in this field
• Read Community – Type a community name in this field
• Write Community – private (no change possible)