ng
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
362
-01
D
TD sensor (Vt) lower limit error: Bk
The Vt value lower limit of the black TD sensor (SP3210-001) falls
below the specified value (SP3211-004) for the specified number of
times (SP3211-005) consecutively.
-02 D
TD sensor (Vt) lower limit error 1: Cy
The Vt value lower limit of the cyan TD sensor (SP3210-002) falls
below the specified value (SP3211-004) for the specified number of
times (SP3211-005) consecutively.
-03 D
TD sensor (Vt) lower limit error 1: Ma
The Vt value lower limit of the magenta TD sensor (SP3210-003) falls
below the specified value (SP3211-004) for the specified number of
times (SP3211-005) consecutively.
-04 D
TD sensor (Vt) lower limit error 1: Ye
The Vt value lower limit of the yellow TD sensor (SP3210-004) falls
below the specified value (SP3211-004) for the specified number of
times (SP3211-005) consecutively.
ï‚§ Black, cyan, magenta, or yellow TD sensor disconnected
ï‚§ Harness between TD sensor and PCDU defective
ï‚§ Defective TD sensor
1. Check the black, cyan, magenta, or yellow TD sensor connector and
harness between the TD sensor and PCDU.
2. Check the drawer connector.
3. Replace the defective TD sensor.