SP Mode
Tables
042 Job End Vb Coefficient *ENG [0 to 100 / 34 / 1%/step]
043 Job End Length *ENG [0 to 99 / 77 / 1mm/step]
044 Job End Supply *ENG
[0.000 to 1.000 / 0.450 /
0.001mg/cm^2/step]
081 Max Counts *ENG
Sets the upper limit of number of toner
refreshes performs at the same time of
process control.
[0 to 50 / 0 / 1/step]
3552 [Blade damage prevention mode]
001
Execution Temp.
Threshold
*ENG
Sets the temperature threshold of blade
damage prevention mode execution.
[0 to 50 / 50 / 1deg/step]
3553 [Transfer belt cleaning]
001
TransferIdleTime
Temperature:H
*ENG
[0.0 to 3.0 / 0.0 / 0.1revolutions/step]
002
TransferIdleTime
Temperature:M
*ENG
003
TransferIdleTime
Temperature:L
*ENG
004
TransferIdleTime
Temperature:L:ON
*ENG
005
Temperature
Threshold:T2
*ENG [20 to 30 / 25 / 1deg/step]
006
Temperature
Threshold:T1
*ENG [0 to 15 / 15 / 1deg/step]
007
Temperature
Threshold:T3
*ENG [0 to 30 / 18 /1deg/step]