Main SP Tables-1
D117/D118 3-12 SM Appendix
1106
[Fusing Temp. Display] Fusing Temperature Display (Heating or Pressure)
Displays the current temperature of the heating and pressure rollers.
001 Center ENG [-50 to 250 / 0 / 1deg/step]
002
End ENG [-20 to 348 / 0 / 1deg/step]
The heating roller has two lamps. One heats the center of the heating roller
and the other heats both ends of the heating roller.
003
Pressure: Center ENG [-20 to 250 / 0 / 1deg/step]
The pressure roller has two lamps. One heats the center of the heating roller
and the other heats both ends of the heating roller.
005 Pressure: End ENG [-20 to 250 / 0 / 1deg/step]
1107 [Standby Target Temp. Setting]
001
Stanby/Preheat1:Center *ENG [0 to 100 / 60 / 1deg/step]
Specifies the time that the fusing heater turns off after the fusing unit
temperature has reached its target temperature.
003
Preheat2:Center *ENG [-50 to 100 / -50 / 1deg/step]
Specifies the temperature of the heating roller for the ready or energy save 2
mode.
005
Low Power:Center *ENG [-50 to 100 / -50 / 1deg/step]
Specifies the temperature of the heating roller for the low power mode.
007
Print Ready:Center *ENG [0 to 180 / 150 / 1deg/step]
Specifies the temperature of the heating roller for the print ready condition.

Table of Contents

Other manuals for Ricoh GR-C1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh GR-C1 and is the answer not in the manual?

Ricoh GR-C1 Specifications

General IconGeneral
BrandRicoh
ModelGR-C1
CategoryAll in One Printer
LanguageEnglish

Related product manuals