Main SP Tables-5
D117/D118 3-318 SM Appendix
5610 [Base Gamma Ctrl Pt:Execute]
004 Get Factory Default ENG
Recalls the factory settings.
[- / - / -]
[Execute]
005 Set Factory Default ENG
Overwrites the current values onto
the factory settings.
[- / - / -]
[Execute]
006 Restore Orginal Value ENG
Recalls the previous settings.
[- / - / -]
[Execute]
5611 [Toner Color in 2C]
001 B-C *ENG
Adjusts the Cyan correction value of
the blue signal in two-color mode.
[0 to 128 / 100 / 1/step]
128: Darkest density
002 B-M *ENG
Adjusts the Magenta correction value
of the blue signal in two-color mode.
[0 to 128 / 100 / 1/step]
128: Darkest density
003 G-C *ENG
Adjusts the Cyan correction value of
the blue signal in two-color mode.
[0 to 128 / 100 / 1/step]
128: Darkest density
004 G-Y *ENG
Adjusts the Yellow correction value of
the blue signal in two-color mode.
[0 to 128 / 100 / 1/step]
128: Darkest density