SC Tables
D117/D118 6-74 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
994
CTL
C
Application Item Error
The number of executed application items on the operation panel reach
the maximum limit for the operation panel structure.
ï‚§ Too many executed application items
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
997
CTL
B
Software Error 3: Cannot select application function
An application does not start after the user pushed the correct key on
the operation panel.
ï‚§ Software bug
ï‚§ A RAM or DIMM option necessary for the application is not installed
or not installed correctly.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
998
CTL
D
Software Error 4: Application cannot start
Register processing does not operate for an application within 60 s
after the machine power is turned on. No applications start correctly,
and all end abnormally.
ï‚§ Software bug
ï‚§ A RAM or DIMM option necessary for the application is not installed
or not installed correctly.