Main SP Tables-7
D117/D118 3-416 SM Appendix
078 Rotation %: Second Image Transfer
079 Measurement %: Toner Correction Bottle
081 Rotation %: Fusing Pad
082 Rotation %: Lubricant: PCU: K
083 Rotation %: Lubricant: PCU: C
084 Rotation %: Lubricant: PCU: M
085 Rotation %: Lubricant: PCU: Y
086 Rotation %: Lubricant: Image Transfer
7906
[Prev. Unit PM Counter]
(Page or Rotations, Unit, [Color]), Dev.: Development Unit
091 to
116
Displays the value given by the following formula:
(Yield count / Current count)
100, where "Current count" is the current values
in the counter for the part, and "Yield count" is the recommended yield.
ENG
[0 to 255 / - / 1 %/step]
091 Page %: PCU: K
092 Page %: PCU: C
093 Page %: PCU: M
094 Page %: PCU: Y
095 Page %: Development Unit: K
096 Page %: Development Unit: C
097 Page %: Development Unit: M
098 Page %: Development Unit: Y
099 Page %: Developer: K
100 Page %: Developer: C
101 Page %: Developer: M