Remote Control Commands
R&S
®
SMBV100A
717Operating Manual 1176.8016.02 ─ 17
The external baseband signal A can be routed to path A, path B, or both paths. The
external baseband signal B can be routed to path B only.
[:SOURce<hw>]:BBIN:ALEVel:EXECute.......................................................................... 717
[:SOURce<hw>]:BBIN:CDEVice?.....................................................................................717
[:SOURce<hw>]:BBIN:CFACtor.......................................................................................717
[:SOURce<hw>]:BBIN:DIGital:ASETting:STATe................................................................ 718
[:SOURce<hw>]:BBIN:FOFFset.......................................................................................718
[:SOURce<hw>]:BBIN:IQSWap[:STATe].......................................................................... 718
[:SOURce<hw>]:BBIN:MPERiod......................................................................................719
[:SOURce<hw>]:BBIN:OLOad:HOLD:RESet.....................................................................719
[:SOURce<hw>]:BBIN:OLOad:HOLD:STATe?.................................................................. 719
[:SOURce<hw>]:BBIN:OLOad:STATe?............................................................................ 720
[:SOURce<hw>]:BBIN:POWer:PEAK............................................................................... 720
[:SOURce<hw>]:BBIN:POWer:RMS?...............................................................................720
[:SOURce<hw>]:BBIN:SRATe[:ACTual]............................................................................721
[:SOURce<hw>]:BBIN:SRATe:FIFO[:STATus]?.................................................................721
[:SOURce<hw>]:BBIN:SRATe:SOURce........................................................................... 721
[:SOURce<hw>]:BBIN:STATe......................................................................................... 722
[:SOURce<hw>]:BBIN:ALEVel:EXECute
This command starts measuring the input signal. The measurement estimates the
crest factor and the peak power.
Example:
BBIN:ALEV:EXEC
starts measuring the input signal.
Usage: Event
Manual operation: See "Auto Level Set" on page 456
[:SOURce<hw>]:BBIN:CDEVice?
Digital Input only.
Indicates the ID of an externally connected R&S Instrument or R&S Device.
Return values:
<CDevice> string
Example:
BBIN:CDEV
queries the connected device ID.
Usage: Query only
Manual operation: See "Connected Device" on page 457