Vision Operator’s Manual (v12.0 MD) Switcher Basics • Ops 4–21
MultiPanel Operational Notes
The following is a list of MultiPanel operational notes that you should keep in mind when using
either a Master Panel, or Satellite Panel, in a MultiPanel configuration:
Each control panel can have a separate Program MLE, but only the highest number MLE
used by a control panel in the system can use the MultiDSK, Half MLE, or Preview
Overlay options, as well as the Preview Bus.
If you change the Program MLE for a control panel, you must set the MLE Program
output for that MLE to the Output BNC you want to use.
If multiple control panels have the same MLE assigned to them, conflicts are decided on
a last button press wins basis.
Satellite Panels cannot perform the following tasks:
Disk/USB Operations
Remote Enables for Editors
System Restart or Shutdown
Device Control
Install Software Options
›Set System Time
Only the Master Panel can connect to external devices; however, a custom control that
performs an action on a device can be run from a Satellite Panel.
OverDrive and Editors can only interface with the Master Panel.
Each control panel in a MultiPanel system, must have a unique IP Address and Panel ID
(such as Satellite 1).
Memories, Custom Controls, Bus Maps, Installation Settings, and Personalities are
shared across all control panels.
Memory recalls only affect the MLEs that are assigned to the control panel that they are
recalled on; however, if the memory is recalled as part of a custom control, it will affect
the MLEs that were assigned to the control panel that the custom control was recorded
on.
Different Bus Maps can be assigned to the same MLE from different control panels.

Table of Contents