Ops 4–22 • Switcher Basics Vision Operator’s Manual (v12.0 MD)
GPI Output Control
A GPI output can be triggered either through a custom control or manually through the GPI
Output Control Menu. The GPI Output Control Menu shows all GPI outputs with the name,
trigger type, and level for each GPI output. If a GPI output is active, the button is lit.
Use the following procedure to manually trigger a GPI output:
1. Navigate to the GPI Output Control Menu as follows:
• Press HOME B Effects B More B More B GPI Outputs.
GPI Output Control Menu
2. Select the Output X button on the GPI Output Control Menu for the GPI output that
you want to trigger or toggle, where X is the number of the GPI output. Active GPI
outputs are shown as lit buttons.
This completes the procedure for manually triggering a GPI output.
For More Information...
• on GPI custom controls, refer to the section “Programming Special Functions” on
page Eng 10-15.
• on setting up GPI inputs and outputs, refer to the section “Standard GPI Setup” on