Captive Portal for Guest Access
13.2 Configuring a WLAN SSID for Guest Access
SCALANCE W1750D UI
168 Configuration Manual, 02/2018, C79000-G8976-C451-02
Client IP Assignment
Client VLAN Assignment
Network assigned If the
Network assigned
is selected, you can specify any of the follow-
ing options for the
Client VLAN assignment
.
•
Default
—On selecting this option, the client obtains the IP address
in the same subnet as the APs. By default, the client VLAN is as-
signed to the native VLAN on the wired network.
•
Static
—On selecting this option, you need to specify a single VLAN,
a comma separated list of VLANS, or a range of VLANs for all cli-
ents on this network.
Select this option for configuring VLAN poo-
ling.
•
Dynamic
—On selecting this option, you can assign the VLANs
dynamically from a Dynamic Host Configuration Protocol (DHCP)
server. To create VLAN assignment rules, click
New
to assign the
user to a VLAN. In the
New VLAN Assignment Rule
window, enter
the following information:
–
Attribute
—Select an attribute returned by the RADIUS server
during authentication.
–
Operator
—Select an operator for matching the string.
–
String
—Enter the string to match
–
VLAN
—Enter the VLAN to be assigned.
9. Click
Next
to configure internal or external captive portal authentication, roles, and access
rules for the guest users.
Note
If the client IP assignment mode is set to Network assigned
in a guest SSID profile, the
guest clients can log out of the captive portal network by accessing the
https://securelogin.scalance.com/auth/logout.html URL.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1750D UI and is the answer not in the manual?

Siemens SCALANCE W1750D UI Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1750D UI
CategoryWireless Access Point
LanguageEnglish

Related product manuals