Hotspot Profiles
33.2 Configuring Hotspot Profiles
SCALANCE W1750D UI
506 Configuration Manual, 02/2018, C79000-G8976-C451-02
Configuring a Roaming Consortium Profile
You can configure a roaming consortium profile to send the roaming consortium information
as an ANQP IE in a GAS query response.
To configure a roaming consortium profile:
(scalance)(config)# hotspot anqp-roam-cons-profile <name>
(scalance)(roaming-consortium <name>)# roam-cons-oi <roam-cons-oi>
(scalance)(roaming-consortium <name>)# roam-cons-oi-len <roam-cons-oi-len>
(scalance)(roaming-consortium <name>)# enable
(scalance)(roaming-consortium <name>)# end (scalance)# commit apply
Specify a hexadecimal string of 35 octets for
roam-cons-oi <roam-cons-oi>
.
Based on the Organization Identifier (OI) specified, you can specify the following parameters
for the length of OI in
roam-cons-oi-len <roam-cons-oi-len>
.
For 0: 0 Octets in the OI (Null)
For 3: OI length is 24-bits (3 Octets)
For 5: OI length is 36-bits (5 Octets)
Configuring a 3GPP Profile
You can configure a 3rd Generation Partnership Project (3GPP) profile to define information
for the 3G Cellular Network for hotspots.
To configure a 3GPP profile:
(scalance)(config)# hotspot anqp-3gpp-profile <name>
(scalance)(3gpp <name>)# 3gpp-plmn1 <plmn-ID>
(scalance)(3gpp <name>)# enable
(scalance)(3gpp <name>)# end
(scalance)# commit apply
The Public Land Mobile Network (PLMN) ID is a combination of the mobile country code and
network code. You can specify up to 6 PLMN IDs for a 3GPP profile.