Set Up Dial-Up Connection via PPP
384 SICAM RTUs, User Manual SICAM CMIC
DC8-001-2.09, Edition 08.2016
If several modems are already installed on the PC, you must select the desired in the tab
General.
In the register tab Networking the settings PPP: Windows 95/98/NT4/2000, Internet,
as well as Internet Protocol (TCP/IP) must be selected. If you are using a stand-
alone computer, the other boxes should remain blank for safety reasons. Mark the line
Internet Protocol (TCP/IP) and then click on Properties.
In this window the items Obtain an IP address automatically and Obtain DNS server
address automatically must be selected. Continue with Advanced….
In the last window of the settings, under the register tab General, the box Use default
gateway on remote network must not be ticked. The field Use IP header compression is
active.
To confirm the input, acknowledge with the OK button. The installation and configuration is
thereby complete.
To set up a connection, click the button Dial in the window “Connect Connection to SIE".