LL ADC Generic Driver
UM1940
768/1371
DocID028236 Rev 2
compare: input capture or output capture).
Trigger edge set to rising edge (default setting).
LL_ADC_INJ_TRIG_EXT_TIM4_CH1
ADC group injected conversion trigger from
external IP: TIM4 channel 1 event (capture
compare: input capture or output capture).
Trigger edge set to rising edge (default setting).
LL_ADC_INJ_TRIG_EXT_TIM4_CH2
ADC group injected conversion trigger from
external IP: TIM4 channel 2 event (capture
compare: input capture or output capture).
Trigger edge set to rising edge (default setting).
LL_ADC_INJ_TRIG_EXT_TIM4_CH3
ADC group injected conversion trigger from
external IP: TIM4 channel 3 event (capture
compare: input capture or output capture).
Trigger edge set to rising edge (default setting).
LL_ADC_INJ_TRIG_EXT_TIM4_TRGO
ADC group injected conversion trigger from
external IP: TIM4 TRGO. Trigger edge set to
rising edge (default setting).
LL_ADC_INJ_TRIG_EXT_TIM5_CH4
ADC group injected conversion trigger from
external IP: TIM5 channel 4 event (capture
compare: input capture or output capture).
Trigger edge set to rising edge (default setting).
LL_ADC_INJ_TRIG_EXT_TIM5_TRGO
ADC group injected conversion trigger from
external IP: TIM5 TRGO. Trigger edge set to
rising edge (default setting).
LL_ADC_INJ_TRIG_EXT_TIM8_CH2
ADC group injected conversion trigger from
external IP: TIM8 channel 2 event (capture
compare: input capture or output capture).
Trigger edge set to rising edge (default setting).
LL_ADC_INJ_TRIG_EXT_TIM8_CH3
ADC group injected conversion trigger from
external IP: TIM8 channel 3 event (capture
compare: input capture or output capture).
Trigger edge set to rising edge (default setting).
LL_ADC_INJ_TRIG_EXT_TIM8_CH4
ADC group injected conversion trigger from
external IP: TIM8 channel 4 event (capture
compare: input capture or output capture).
Trigger edge set to rising edge (default setting).
LL_ADC_INJ_TRIG_EXT_EXTI_LINE15
ADC group injected conversion trigger from
external IP: external interrupt line 15. Trigger
edge set to rising edge (default setting).
ADC group injected - Automatic trigger mode
LL_ADC_INJ_TRIG_INDEPENDENT
ADC group injected conversion trigger
independent. Setting mandatory if ADC
group injected injected trigger source is
set to an external trigger.
LL_ADC_INJ_TRIG_FROM_GRP_REGULAR
ADC group injected conversion trigger
from ADC group regular. Setting compliant
only with group injected trigger source set
to SW start, without any further action on
ADC group injected conversion start or