EasyManuals Logo
Home>Tektronix>Test Equipment>TBS2000 Series

Tektronix TBS2000 Series User Manual

Tektronix TBS2000 Series
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #201 background imageLoading...
Page #201 background image
MEASUrement:MEAS<x>:SOUrce1
Sets or queries the source for all single source measurements and specifies the
source to measure from when taking a delay measurement or phase measurement.
Where <x> identifies the measurement, 1 through 6.
This is equivalent to selecting the measurement source in the MEASURE menu.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:SOUrce1 {CH<x>|MATH}
MEASUrement:MEAS<x>:SOUrce1?
Arguments
CH<x> specifies the input channel source for the measurement.
MATH specifies the measurement source channel as the math waveform.
Examples
MEASUREMENT:MEAS2:SOURCE1 CH1 sets source1 for Measurement 2 to
channel 1.
MEASUrement:MEAS1:SOUrce1? might
return :MEASUrement:MEAS1:SOUrce1 MATH indicating the source for
measurement 1 is the math waveform.
M commands
TBS2000 Series Programmer 183

Table of Contents