MEASUrement:MEAS<x>:SOUrce2
Sets or queries the reference source to measure to when taking a delay or phase
measurement. Where <x> identifies the measurement, 1 through 6.
NOTE. Source2 measurements only apply to phase and delay measurement types,
which require both a target (Source1) and reference (Source2) source.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:SOUrce2 {CH<x>|MATH}
MEASUrement:MEAS<x>:SOUrce2?
Related commands
MEASUrement:MEAS<x>:TYPe on page 186
Arguments
CH<x> specifies the input channel source for the measurement, where x is the
channel number.
MATH specifies the measurement source channel as the math waveform.
Examples
MEASUrement:MEAS1:SOUrce2 CH1 sets source2 for Measurement 2 to
channel 1.
MEASUrement:MEAS1:SOUrce2? might
return :MEASUrement:MEAS1:SOUrce2 MATH indicating the to source for
measurement 1 is the math waveform.
M commands
184 TBS2000 Series Programmer