Arguments
<NR3> specifies the minimum width, in seconds.
Examples
TRIGGER:A:RUNT:WIDTH 15E-6 sets the minimum pulse width of the runt
trigger to 15 μs.
TRIGGER:A:RUNT:WIDTH? might
return :TRIGGER:A:PULSE:RUNT:WIDTH 2.0000E-09 indicating that the
minimum pulse width of a runt trigger is 2 ns.
TRIGger:A:TYPe
Sets or queries the type of A trigger. This is equivalent to setting the Type option
in the Trigger menu.
Group
Trigger
Syntax
TRIGger:A:TYPe{EDGe|PULSe}
TRIGger:A:TYPe?
Related commands
TRIGger:A:EDGE? on page 224, TRIGger:A:PULse:CLAss on page 232
Arguments
EDGE is a normal trigger. A trigger event occurs when a signal passes through a
specified voltage level in the specified direction and is controlled by the
TRIGger:A:EDGE commands.
PULse specifies that a trigger occurs when the specified signal meets the pulse
width criteria that is controlled by the TRIGger: A:PULse commands.
Examples
TRIGGER:A:TYPE EDGE sets the A trigger type to EDGE.
TRIGGER:A:TYPE? might return :TRIGGER:A:TYPE PULSE indicating that
the A trigger type is a pulse trigger.
T commands