Syntax
TRIGger:A:LOWerthreshold:CH<x> {ECL|TTL|<NR3>}
TRIGger:A:LOWerthreshold:CH<x>?
Related commands
TRIGger:A:LEVel:CH<x> on page 229
Arguments
ECL specifies a preset ECL high level of -1.3 V.
TTL specifies a preset TTL high level of 1.4 V.
<NR3> is the clock level, in volts.
Examples
TRIGGER:A:LOWERTHRESHOLD:CH2 50E-3 sets the lower limit threshold
for CH2 of the pulse runt trigger to 50 mV.
TRIGGER:A:LOWERTHRESHOLD:CH2? might return :TRIGGER:A:
LOWERTHRESHOLD:CH2 1.2000E-01 indicating that the lower limit threshold
for CH2 of the pulse runt trigger is set to 120 mV.
TRIGger:A:MODe
Sets or queries the trigger mode.
Group
Trigger
Syntax
TRIGger:A:MODe {AUTO|NORMal}
TRIGger:A:MODe?
Related Commands
TRIGger:A:LEVel on page 228
T commands
230 TBS2000 Series Programmer