Syntax
CH<x>:BANdwidth {TWEnty|FULl|<NR3>}
CH<x>:BANdwidth?
Arguments
TWEnty sets the upper bandwidth limit of channel <x> to 20 MHz.
FULl disables any optional bandwidth limiting. The specified channel operates at
its maximum attainable bandwidth.
<NR3> is a double-precision ASCII string. The instrument rounds this value to
an available bandwidth using geometric rounding, and then uses this value to set
the upper bandwidth limit.
NOTE. Other values may be possible depending on the attached probes.
Examples
CH1:BANDWIDTH TWENTY sets the bandwidth of channel 1 to 20 MHz.
CH1:BANDWIDTH? might return FULl. This indicates there is no bandwidth
limiting on channel 1.
CH<x>:COUPling
Sets or queries the input attenuator coupling setting of the specified instrument
channel. The value of <x> can vary from 1 through 4 depending on the
instrument model.
This command is equivalent to setting the Coupling option in the Vertical menu.
Group
Vertical
Syntax
CH<x>:COUPling {AC|DC|GND}
CH<x>:COUPling?
C commands
TBS2000 Series Programmer 61

Table of Contents

Other manuals for Tektronix TBS2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TBS2000 Series and is the answer not in the manual?

Tektronix TBS2000 Series Specifications

General IconGeneral
BrandTektronix
ModelTBS2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals