Command Description
WFMInpre:BYT_Nr on page 250 Sets or queries the data width for the waveform
to be transferred.
WFMInpre:ENCdg on page 250 Sets or queries the type of encoding for
waveform data transferred with the CURVe
command.
WFMInpre:NR_Pt? on page 251 Returns the number of points that are in the
transmitted waveform record, as specified by
DATa:SOUrce.
WFMInpre:XINcr on page 252 The set form of this command specifies the
interval (seconds per point for nonFFT, Hertz
per point for FFT) between samples of the
reference waveform specified by the
DATa:DESTination command.
WFMInpre:XUNit on page 252 Sets the horizontal units ("s" for seconds and
"Hz" for Hertz) for the reference waveform
specified by the DATa:DESTination command.
WFMInpre:XZEro on page 253 The set form of this command specifies the
position, in XUNits, of the first sample of the
reference waveform specified by the
DATa:DESTination command, relative to the
trigger.
WFMInpre:YMUlt on page 254 Sets or queries the vertical scale factor of the
incoming waveform, expressed in YUNits per
waveform data point level.
WFMInpre:YOFf on page 255 Sets or queries the vertical position of the
incoming waveform in digitizing levels.
WFMInpre:YUNit on page 255 Sets the vertical units for the reference
waveform specified by DATa:DESTination.
WFMInpre:YZEro on page 256 Sets or returns the vertical offset of the incoming
waveform in units specified by WFMInpre:YUNit.
WFMOutpre? on page 257 Returns waveform transmission and formatting
settings for the waveform specified by the
DATa:SOUrce command.
WFMOutpre:BIT_Nr on page 258 Sets and queries the number of bits per
waveform point that outgoing waveforms
contain, as specified by the DATa:SOUrce
command.
WFMOutpre:BYT_Nr on page 259 Sets or queries the data width for the outgoing
waveform specified by the DATa:SOUrce
command.
WFMOutpre:ENCdg on page 260 Sets and queries the type of encoding for
outgoing waveforms.
WFMOutpre:NR_Pt? on page 261 Returns the number of points for the
DATa:SOUrce waveform that will be transmitted
in response to a CURVe? query.
Command groups
TBS2000 Series Programmer 31

Table of Contents

Other manuals for Tektronix TBS2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TBS2000 Series and is the answer not in the manual?

Tektronix TBS2000 Series Specifications

General IconGeneral
BrandTektronix
ModelTBS2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals