B.3 Parameter Table
498 YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
L5: Fault Restart
L6: Torque Detection
No. (Addr.) Name Description Setting Page
L5-01
(49EH)
Number of Auto Restart Attempts
Sets the number of times the drive may attempt to restart after the following faults occur: GF,
LF, oC, oH1, ov, PF, rH, rr, oL1, oL2, oL3, oL4, STo, Uv1.
Default: 0
Min: 0
Max: 10
290
L5-02
(49FH)
Auto Restart Fault Output
Operation Selection 0: Fault output not active.
1: Fault output active during restart attempt.
Default: 0
Min: 0
Max: 1
290
L5-04
(46CH)
Fault Reset Interval Time
Sets the amount of time to wait between performing fault restarts.
Default: 10.0 s
Min: 0.5 s
Max: 600.0 s
290
L5-05
(467H)
Fault Reset Operation Selection
0: Continuously attempt to restart while incrementing restart counter only at a successful
restarts (same as F7 and G7).
1: Attempt to restart with the interval time set in L5-04 and increment the restart counter with
each attempt (same V7).
Default: 0
Min: 0
Max: 1
291
No. (Addr.) Name Description Setting Page
L6-01
(4A1H)
Torque Detection Selection 1
0: Disabled
1: oL3 detection only active during speed agree, operation continues after detection
2: oL3 detection always active during run, operation continues after detection
3: oL3 detection only active during speed agree, output shuts down on an oL3 fault
4: oL3 detection always active during run, output shuts down on an oL3 fault
5: UL3 detection only active during speed agree, operation continues after detection
6: UL3 detection always active during run, operation continues after detection
7: UL3 detection only active during speed agree, output shuts down on an oL3 fault
8: UL3 detection always active during run, output shuts down on an oL3 fault
Default: 0
Min: 0
Max: 8
292
L6-02
(4A2H)
Torque Detection Level 1
Sets the overtorque and undertorque detection level.
Default: 150%
Min: 0%
Max: 300%
292
L6-03
(4A3H)
Torque Detection Time 1
Sets the time an overtorque or undertorque condition must exist to trigger torque detection 1.
Default: 0.1 s
Min: 0.0 s
Max: 10.0 s
292
L6-04
(4A4H)
Torque Detection Selection 2
0: Disabled
1: oL4 detection only active during speed agree, operation continues after detection
2: oL4 detection always active during run, operation continues after detection
3: oL4 detection only active during speed agree, output shuts down on an oL4 fault
4: oL4 detection always active during run, output shuts down on an oL4 fault
5: UL4 detection only active during speed agree, operation continues after detection
6: UL4 detection always active during run, operation continues after detection
7: UL4 detection only active during speed agree, output shuts down on an oL4 fault
8: UL4 detection always active during run, output shuts down on an oL4 fault
Default: 0
Min: 0
Max: 8
292
L6-05
(4A5H)
Torque Detection Level 2
Sets the overtorque and undertorque detection level.
Default: 150%
Min: 0%
Max: 300%
292
L6-06
(4A6H)
Torque Detection Time 2
Sets the time an overtorque or undertorque condition must exist to trigger torque detection 2.
Default: 0.1 s
Min: 0.0 s
Max: 10.0 s
292
L6-08
(468H)
Mechanical Weakening Detection
Operation
This function can detect an overtorque or undertorque in a certain speed range as a result of
machine fatigue. It is triggered by a specified operation time and uses the oL1 detection settings
(L6-01 and L6-03)
0: M
echanical Weakening Detection disabled.
1: Continue running (alarm only). Detected when the speed (signed) is greater than L6-09.
2: Continue running (alarm only). Detected when the speed (not signed) is greater than L6-09.
3: Interrupt drive output (fault). Detected when the speed (signed) is greater than L6-09.
4: Interrupt drive output (fault). Detected when the speed (not signed) is greater than L6-09.
5: Continue running (alarm only). Detected when the speed (signed) is less than L6-09.
6: Continue running (alarm only). Detected when the speed (not signed) is less than L6-09.
7: Interrupt drive output (fault). Detected when the speed (signed) is less than L6-09.
8: Interrupt drive output (fault). Detected when the speed (not signed) is less than L6-09.
Default: 0
Min: 0
Max: 8
293
L6-09
(469H)
Mechanical Weakening Detection
Speed Level
Sets the speed that triggers Mechanical Weakening Detection. When L6-08 is set for an
unsigned value, the absolute value is used if the setting is negative.
Default: 110.0%
Min: -110.0%
Max: 110.0%
293
L6-10
(46AH)
Mechanical Weakening Detection
Time
Sets the time mechanical weakening has to be detected before an alarm or fault is triggered.
Default: 0.1 s
Min: 0.0 s
Max: 10.0 s
293
L6-11
(46BH)
Mechanical Weakening Detection
Start Time
Sets the operation time (U4-01) required before Mechanical Weakening Detection is active.
Default: 0 h
Min: 0 h
Max: 65535 h
294
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes

Table of Contents

Other manuals for YASKAWA A1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA A1000 and is the answer not in the manual?

YASKAWA A1000 Specifications

General IconGeneral
TypeAC Drive
SeriesA1000
Input Voltage200-240V, 380-480V
Frequency Range0-400 Hz
Horsepower Range0.5 to 1000 HP
Power Range0.4 to 630 kW
Control MethodV/f Control
Overload Capacity150% for 60 seconds
BrakingDynamic Braking
CommunicationModbus
SafetySafe Torque Off (STO)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Operating Temperature-10 to +50°C
Storage Temperature-20 to 60°C
Humidity5 to 95% RH (non-condensing)
EnclosureIP20