8 System Setup
DX100 8.15 Numeric Key Customize Function
8-110
2. Select “ANALOG OUTPUT”.
The output port number and the output voltage value are displayed
in the “ALLOCATION CONTENT”.
(1) To change the output port No. or output voltage value, move the
cursor to the No. or voltage value and press [SELECT]. Then
numeric value can be entered.
(2) Input the number or voltage value to be changed, and press
[ENTER]
8.15.3.10 Analog Incremental Output Allocation
Set this function in the KEY ALLOCATION (SIM) window.
1. Move the cursor to the “FUNCTION” of the key to be allocated and
press [SELECT].
A selection list appears.
2. Select “ANALOG INC OUTPUT.”
The output port No. and incremental value are displayed in the
“ALLOCATION CONTENT”.
(1) To change the output port No. or incremental value, move the cur-
sor to the No. or incremental value and press [SELECT]. Then
numeric values can be entered.
(2) Input the number or incremental value to be changed, and press
[ENTER].