1-7
IM DLM4038-02EN
Bit Settings (Bit Setup)
Press the Bit Setup soft key to display the following screen.
For Logic Probes Other Than the 701989
Turns the display on or off for all bits
Turn the display on or off and set the label for each bit.
Set the threshold level preset (CMOS(5 V), CMOS(3.3 V),
CMOS(2.5 V), CMOS(1.8 V), ECL, Userdef).
Selecting a preset automatically sets the threshold level.
Set the threshold level.
If you change the automatically specified value, the preset
setting changes to “Userdef.”
For the 701989 Logic Probe
• When the Threshold Type is All
Turn the display on or off and set the label for each bit.
Set the noise rejection ( , ).
The threshold type is set to All.
Set the threshold level.
If you change the automatically specified value, the
preset setting changes to “Userdef.”
Set the threshold level preset (CMOS(5 V), CMOS
(3.3 V), CMOS(2.5 V), CMOS(1.8 V), ECL, Userdef).
Selecting a preset automatically sets the threshold
level.
Turns the display on or off for all bits
• When the Threshold Type is Each
Turn the display on or off and
set the label for each bit.
Set the threshold level preset (CMOS(5 V), CMOS
(3.3 V), CMOS(2.5 V), CMOS(1.8 V), ECL, Userdef).
• Selecting a preset automatically sets the threshold
level.
• When the threshold type is Each, set the threshold
level for each bit.
The threshold type is set to Each.
Set the threshold level.
• When the threshold type is Each, set the threshold
level for each bit.
• If you change the automatically specified value,
the preset setting changes to “Userdef.”
Set the noise rejection ( , ).
Turns the display on or off for all bits
Note
For logic probes other than the 701989, the threshold type is All and the ThresholdType setting does not
appear.
1.2 Setting the Vertical Axis for 8-bit LOGIC(L)