S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_prog_generic_step4_ac.fm
Step 4: Make Connection
Example 10. Programming Example
OUTPUT Test_set;CALL:PAG:PNUM 0000574016’”! Set paging number
OUTPUT Test_set;CALL:PAG:REP ON ! Set paging repeat state
OUTPUT Test_set;CALL:ORIG ! Start a base station originated call
OUTPUT Test_set;CALL:CONN? ! Hanging GPIB query
ENTER Test_set;Call_connected ! Program hangs here until
! origination passes or fails
IF NOT Call_connected THEN
OUTPUT Test_set;CALL:END
! <put error handler here>
END IF
! Call is connected so proceed with control program
Process for Making a Mobile Station Originated Call Figure 15. Process for Making a Mobile
Station Originated Call
Yes
No
Start
Originate a call
from mobile station.
Enter response from
CALL:CONN? query.
Call
connected?
Proceed with
control program.
Send CALL:END
command.
Invoke error
handler.
Send
CALL:CONN?
query command.
Send
CALL:CONN:ARM
command.
Send
CALL:CONN:TIM
command.

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals